Z-6A
The
digital small control unit Z-6a is a
multi-zone system with switching power supply and internal fully
digital power amplifier (250W / 100V).
The Z-6a is equipped with
6 speaker zones,
RS-485 interfaces for
digital desktop microphone stations of the
DPM series and front slot for digital playback media modules.The small control unit is a complete
public address control center. The built-in fully digital power amplifier with an output power of 250 watts/100 V can drive
6 separate speaker lines via separate volume control and switch panels.
The device has
3 electronic balanced inputs for microphone or line level (combo jacks),
2 unbalanced line inputs and
switchable phantom power for condenser microphones.
In addition, the Z-6a small central unit has the option of inserting a
sound player module into the empty space provided for this purpose (
PTP-6 FM/AM tuner module). Standard built-in are DIN alarms, 2-4 tone gong (REMOTE output) and 1-tone pregong (settings are made at the desktop station by DIP switches).
Numerous adjustment options make the Z-6a small central unit a problem solver in many applications.
As optional supplement is available e.g. telephone module TPC-6 (telephone paging card) with direct telephone extension input, analogue A/B with priority and ALL-CALL, SOFTWARE-1, SOFTWARE-2. The choice of software through the JUMPER setting on the TPC-6 card allows you to select selective voice announcements to the 6 speaker zones and group formation, free programming of the base collector TR and auxiliary relays.
As optional supplement also the desktop station input module MSP-6 (RS 485) with 2 x RJ-45 to connect up to 15 x microprocessor-controlled DPM-6 or DPM-12 desktop microphone stations and TPC-6 telephone paging card for telephone remote control is available.
In addition, the Z-6a multi-zone system has the following features:
-
Test input for monitoring the output stage with 22 kHz pilot tone
-
Digital message input with priority for connecting the digital voice recorder (external)
-
Priority DC-Out 24V / 200mA output to control the volume knob controls
-
PTT desktop station input with pregone, master / slave function of digital desktop stations
-
Loop-in coupling socket PWR-INPUT / MIX-OUTPUT
-
POWER REMOTE for remotely switching on / off the amplifier system
-
AC / DC manager with automatic switching between AC / DC power supply
The speaker zones are equipped with
2-pin RELAYS and prevent the annoying signal cross-fading of the speaker lines. There are also
2-point EQ per input and control jacks for pause-GONG, ALARM, POWER-REMOTE, PRIORITY.
The Z-6a systems can be networked through the
RS 485 MASTER-SLAVE-INTERFACES. This allows
up to 12 speaker lines (2 x Z-6a) to be set up on 2-CHANNEL (Program-1, Z-6a-1 and Program-2, Z-6a-2) with 500 watts/100V power.
The management of the speaker lines is done by the
DPM-12 desktop microphone station, MSP-MS master card (desktop station input module), MSP-SL slave (desktop station input module) as well as the input INTERFACE (12-zone-switch + ALARM-key).
The control software of the desktop stations is divided into three groups:
-
STANDARD 6 (for 6 zones, DPM-6 desktop stations)
-
STANDARD 12 (for 12 zones, DPM-12 desktop stations)
-
STANDARD 6+6 (for 6 zones, DPM-12-PLUS with the assignment of background music and voice announcements on a Z-6a system)

Specials
-
Supply of 6 speaker zones
-
Build up to 12 speaker zones by connecting 2 x Z-6a with a total of 500 W power
-
RS-485 interfaces for Phoenix DPM series digital system desktop stations
-
Insertion slot for digital playback media modules
-
Fully digital power amplifier (250 W/100 V), IEC 268-3
-
3 x electronic balanced inputs for microphone or line level (combo jacks)
-
2 x cinch balanced line inputs
-
Phantom power
-
DIN alarms, 2-4 sound gong, 1-sound pregong
-
Numerous adjustment options
-
Optional, e.g. telephone module, remote input cards
-
TEST input for 20/22 kHz test signal
-
Digital message input with volume control and priority
-
MULTI LEVEL PRIORITY system
-
Digital message input with volume control and priority
-
AC/DC manager
-
2-point EQ per input
Product safety information
Manufacturer information:
PHOENIX Professional Audio GmbH
Hermann-Oberth-Str. 12
Bayern
Bruckmühl, Deutschland, 83052
info@phoenix-pa.com
https://www.phoenix-pa.com

Technical Details
Audio sensitivity |
MIC 1, 2, 3 balanced (-50dBu / 2.45mV / 1kOHM) to (-10dBu / 245mV / 10kOHM) & PAGING MIC |
Audio output |
MIX Output |
Battery |
Input 24VDC with AC / DC Manager |
Colour |
Graphite, black |
Dimensions |
without 19" mounting angle - 430 mm (W) x 133 mm (H) x 360 mm (D), (19" -3 U) |
Equalization EQ |
LF / HF (+/- 12dB) |
Fernanschaltung |
Yes |
Frequency response |
40 Hz to 20,000 Hz (-1 dB) |
Gain control |
Yes |
Insert |
(PWR INPUT / MIX OUTPUT) |
Mounting |
19"- mounting angle |
Mounting height |
3 HE |
Output |
digital power amplifier with 250 watts according to IEC 268-3, short-circuit proof, no-load |
Output PRO-OUT |
Yes |
Signal to Noise Ratio |
MIC. Inputs: greater than 70dB / Line Inputs: greater than 80dB ("A" Weight) |
Sound adjuster sum |
(+/- 10 dB) at LF-100Hz / HF-10kHz |
Weight |
about 9 kg |